Refine Your Search

Topic

Search Results

Standard

CHARGER FOR BATTERY POWERED GROUND SUPPORT EQUIPMENT

1996-07-01
HISTORICAL
ARP1816B
This SAE Aerospace Recommended Practice (ARP) describes an industrial battery charger, solid state type, hereafter called charger, for use in charging lead acid batteries in ground support equipment.
Standard

GROUND EQUIPMENT - 400 HERTZ GROUND POWER PERFORMANCE REQUIREMENTS

1996-06-01
HISTORICAL
ARP5015
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
HISTORICAL
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

AIRCRAFT CARGO CONVEYOR - BATTERY POWERED

1994-12-01
HISTORICAL
ARP1836A
This SAE Aerospace Recommended Practice (ARP) outlines the functional and design requirements for a battery powered, self-propelled belt conveyor for handling baggage and cargo at aircraft bulk cargo holds.
Standard

AIRCRAFT CARGO CONVEYOR - BATTERY POWERED

1992-12-01
HISTORICAL
ARP1836
This Recommended Practice outlines the functional and design requirements for a battery powered, self propelled belt conveyor for handling baggage and cargo at aircraft bulk cargo holds.
Standard

MAINTENANCE OF BATTERIES AND BATTERY CHARGING AND SERVICING FACILITIES

1992-06-10
HISTORICAL
AIR1898
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

EFFECTS OF NO-BREAK POWER TRANSFER ON 400 HZ AUXILIARY-POWER UNITS AND GROUND-POWER UNITS

1992-02-01
CURRENT
AIR4651
This SAE Aerospace Information Report (AIR) describes the characteristics and effects of using no-break power transfer (NBPT) methods when switching between auxiliary-power unit (APU) and ground-power unit (GPU). The GPU may be: a Point-of-use solid-state frequency converter, engine-generator, or motor-generator b Central system powered by motor-generator or solid-state frequency converter
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

ELECTRICAL CONNECTORS FOR USE IN BATTERY POWERED GROUND SUPPORT EQUIPMENT

1991-04-29
HISTORICAL
ARP1892A
This recommended practice describes a two-pole electric connector for use in battery powered ground support equipment, i.e., traction batteries. Alternatively, the connector can have two or more auxiliary contacts for auxiliary circuits. A handle may be added as an option to assist in connecting and disconnecting.
Standard

CHARGER FOR BATTERY POWERED GROUND SUPPORT EQUIPMENT

1991-04-01
HISTORICAL
ARP1816A
This recommended practice describes an industrial battery charger, solid state type, hereafter called charger, for use in charging lead acid batteries in ground support equipment.
Standard

SOLID-STATE FREQUENCY CONVERTER 400 HERTZ, 3-PHASE OUTPUT

1989-09-01
HISTORICAL
ARP1940
This specification covers the requirements for solid-state frequency converters with 480 [or 380] V 3-phase, 60 [or 50] Hz input and 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704D quality power. The frequency converter shall be a self-contained unit suitable for the environment of intended use. Typical applications include dedicated use at passenger loading bridges (mounted under the bridge in telescoping bridge applications or fixed installation at base of stationary type loading bridges) with weatherproof enclosures or hangar/lab use where indoor fixed or portable units can be used.
Standard

ELECTRIC BAGGAGE/CARGO TRACTOR

1989-04-01
HISTORICAL
ARP1804
This document outlines the functional and design requirements for a battery-powered electric tow tractor in the handling of baggage or cargo trailers in airline service.
Standard

GROUND ELECTRICAL POWER UNIT BRUSHLESS, SYNCHRONOUS, ELECTRIC MOTOR-DRIVEN 400 HERTZ, 3-PHASE OUTPUT

1985-08-01
HISTORICAL
ARP1480
This recommended practice outlines the general requirements of a continuous duty, electric motor-driven brushless alternator unit for supplying 400 Hz electrical power to high performance commercial transport aircraft. This specification is for a single motor-generator set with one or two outputs. The generator set will generate at the aircraft voltage of 115/200 volts. This unit may be used in a central system of small size or in hangar or electronic shop applications. Power characteristics of this unit at the receptacle will meet MIL-Standard-704 requirements. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

ELECTRICAL CONNECTORS FOR USE IN BATTERY POWERED GROUND SUPPORT EQUIPMENT

1985-07-01
HISTORICAL
ARP1892
This recommended practice describes a two-pole electric connector for use in battery powered ground support equipment i.e. traction batteries. Alternatively, the connector can have two or more auxiliary contacts for auxiliary circuits. A handle may be added as an option to assist in connecting and disconnecting.
Standard

CHARGER FOR BATTERY POWERED GROUND SUPPORT EQUIPMENT

1984-09-01
HISTORICAL
ARP1816
This recommended practice describes an industrial battery charger, solid state type, hereafter called charger, for use in charging lead acid batteries in ground support equipment.
Standard

GROUND EQUIPMENT REBUILD PROGRAM

1979-04-01
HISTORICAL
AIR1599
This AIR is intended to be concerned with fleet programs rather than programs for individual units. Technical and administrative considerations in developing an approach to a program will be suggested Organization of material possibly wanted in the form of a detailed specification for airline rebuilder communication is reviewed.
Standard

VEHICLE ELECTRICAL SYSTEMS

1975-05-01
HISTORICAL
AIR1336
This document considers the following major areas: 1 Major components and their ratings 2 Selection criteria for optimum design balance for electrical systems 3 Effects of operating conditions and environment on both maintenance and life of components 4 Trouble signals -- their diagnosis and cure
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
X